We are acknowledged by our clients as the reckoned entity, engaged in manufacturing and exporting Gas Fired Thermic Fluid Heater. We manufacture this heater at our modern production unit using high quality materials in compliance with the quality standards set by the industry. Our heater is demanded by the industries for ensuring optimum heat transfer. We are offering this Gas Fired Thermic Fluid Heater to our clients at a competitive price.
Features:
Further Details
Technical Specification | |||||||||||||
CAPACITY | 1,00,000 Kcal/Hr TO 50,00,000 KcaL/Hr | ||||||||||||
TEMPERATURE | Up to 350 C | ||||||||||||
FUEL | L.D.O./GAS / DESSEL | ||||||||||||
FIRING MODE | AUTOMETIC BURNER FIRED SYSTEMS | ||||||||||||
FURNACE | INTERNAL FURNACE |
Technical Specifications:
DESCRIPTION | UNITS | DP-0400 | DP-0600 | DP-1000 | DP-1500 | DP-2000 | DP-2500 | DP-4000 | DP-4500 |
Capacity | Kcal/ hr | 400000 | 6,00,000 | 1,000,000 | 1,500,000 | 2,000,000 | 2,500,000 | 4,000,000 | 4,500,000 |
Max. Outlet temperature SS | Deg C | 280 | |||||||
Des Flow O thermic Fluid | M3/h | 20 | 30 | 50 | 80 | 100 | 125 | 240 | 250 |
Max. Head Available At Heater Outlet | mIc/bar | 20/1.45 | |||||||
Thermic Fluid Temperature Riss S | Deg C | 40 | 40 | 40 | 40 | 40 | 40 | 33 | 36 |
| | Fuel Firing Parameter | |||||||
Fuel Consumption-Hsd | Kg/h | 44.30 | 66.45 | 110.74 | 166.11 | 221.48 | 276.85 | 435.7 | 490.2 |
LDO | Kg/h | 45.60 | 68.40 | 114.00 | 171.00 | 228.00 | 285.00 | 461.4 | 519.0 |
FO | Kg/h | 48.320 | 72.30 | 120.50 | 180.75 | 240.99 | 301.24 | | |
Natural Gas | Nm3/h | 55.36 | 83.04 | 138.41 | 207.61 | 276.82 | 346.02 | 553.6 | 622.8 |
LPG | Nm3/h | 18.87 | 28.30 | 47.17 | 70.76 | 94.34 | 117.93 | 188.7 | 212.3 |
Fuel NCV - HSD | Kcal/h | 10,500.00 | |||||||
LDO | Kcal/h | 10,200.00 | |||||||
FO | Kcal/h | 9,650.00 | |||||||
Natural Gas | Kcal/nm3 | 8,500.00 | |||||||
LPG | Kcal/nm3 | 24,940.00 | |||||||
Thermal Efficiency -Ido/hsd | % on NCV | 86+/-2 | |||||||
FO | % on NCV | 86+/-2 | |||||||
Natural Gas / Lpg | % on NCV | 85+/-2 | |||||||
Burner Control | | Single / Two Stage 33-100% Stepless | |||||||
Electrical Connected Load | | Electric Supply- 415 or 380 Volt AC+/6%Hz+/-3%,3 Phase | |||||||
Burner motor | kW | 0.75 | 1.50 | 4.0 | 5.5 | 7.5 | 5.5 | 18.5 | 21.7 |
Fuel Pump motor | kW | Part of Burner | |||||||
Oil Preheater (inbuilt in burner) | kW | 3.0 | 3.0 | 6.0 | 12.0 | 12.0 | 12.0 | | |
Thermic Fluid Circulation Pump Motor | kW | 5.5 | 11.0 | 11.0 | 11.0 | 15.0 | 15.0 | 45 | 55 |
Total (incl control panel )- Hsd/Iod | kW | 6.75 | 13.0 | 21.5 | 29.0 | 35 | 33.0 | 64.5 | 77.7 |
NG/LPG | kW | 6.8 | 13.0 | 15.5 | 29.0 | 35.0 | 33.0 | 64.5 | 77.7 |
FO | kW | 9.75 | 16 | 21.5 | 29.0 | 35.0 | 33.0 | 64.0 | 77.2 |
Dimensions | | | |||||||
Length/height | metres | 2.66 | 2.96 | 3.16 | 3.86 | 4.31 | 4.71 | 75 | 8.5 |
Diameter | metres | 1.59 | 1.62 | 1.90 | 2.17 | 2.40 | 2.64 | | |
Type of Heater Installation | | Vertical of Horizontal | |||||||
Main unit Weight (dry =) (w/o Burner) | kg | 2200 | 3000 | 4200 | 5800 | 7700 | 10500 | 16000 | 19000 |
De tank weight (dry) | kg | 300 | 300 | 450 | 570 | 770 | 910 | | |
Volumetric Capacity Of D/e tank | liters | 500 | 500 | 1000 | 1500 | 2000 | 3000 | | |
Volumetric Of Coll | liters | 318 | 360 | 675 | 1250 | 1600 | 2040 | 4000 | 5900 |